{"id":786,"date":"2019-10-10T08:55:02","date_gmt":"2019-10-10T08:55:02","guid":{"rendered":"https:\/\/lindy.com\/fr\/?post_type=lin-technology&#038;p=786"},"modified":"2019-11-11T15:33:09","modified_gmt":"2019-11-11T15:33:09","slug":"construction-du-cable","status":"publish","type":"lin-technology","link":"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/","title":{"rendered":"Patch Cable Shielding"},"content":{"rendered":"\n<section class=\"wp-block-lindy-image-text-module section section--full-width-image full-width-image--with-text theme--light section--animation-none align--center  font--size-medium\" style=\"background-image:url(https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg)\"><img decoding=\"async\" class=\"full-width-image__image\" src=\"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg\"\/><div class=\"contained\"><div class=\"full-width-image__content\"><h2 class=\"section__heading\"><span>CONSTRUCTION DU C\u00c2BLE<\/span><\/h2><h2 class=\"section__subheading section__subheading__title\">C\u00c2BLES R\u00c9SEAU &amp; LEURS TYPES DE BLINDAGE<\/h2><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-paragraph-one-col section section--horizontal-content section--horizontal-content--one-column font--size-small theme--dark align--center  section--animation-up\"><div class=\"contained\"><p class=\"section__paragraph\">Les c\u00e2bles \u00e0 paires torsad\u00e9es se composent g\u00e9n\u00e9ralement de quatre paires de fils torsad\u00e9es. La torsion sert \u00e0 minimiser la capacit\u00e9 parasite, qui autrement alt\u00e8re massivement la qualit\u00e9 de transmission d&rsquo;un c\u00e2ble, en particulier dans les bandes de haute fr\u00e9quence avec des valeurs \u00e9lev\u00e9es d&rsquo;att\u00e9nuation du signal, lorsque les paires de fils sont parall\u00e8les les unes aux autres.<br\/><br\/>Les quatre paires de fils sont \u00e9galement torsad\u00e9es ensemble dans le c\u00e2ble pour minimiser la diaphonie de pr\u00e8s et de loin entre les paires (NeXT et FeXT). Ce faisceau de c\u00e2bles s&rsquo;appelle le noyau du c\u00e2ble et est recouvert par la gaine du c\u00e2ble. Selon le type de blindage, les paires torsad\u00e9es individuelles ou le noyau du c\u00e2ble (ou les deux ou aucun) sont entour\u00e9s d&rsquo;un feuillard m\u00e9tallique ou d&rsquo;une tresse.<\/p><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-image-text-module section section--full-width-image full-width-image--with-text theme--light section--animation-none align--left  font--size-medium\" style=\"background-image:url(https:\/\/lindy.com\/fr\/wp-content\/uploads\/sites\/4\/2019\/10\/Animation-Nomenklatur_FR-6.gif)\"><img decoding=\"async\" class=\"full-width-image__image\" src=\"https:\/\/lindy.com\/fr\/wp-content\/uploads\/sites\/4\/2019\/10\/Animation-Nomenklatur_FR-6.gif\"\/><div class=\"contained\"><div class=\"full-width-image__content\"><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-key-info section section--key-info theme--light section--animation-none\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"box\"><h3 class=\"section__heading\">\nNomenclature du blindage<\/h3><div class=\"section__content\"><p class=\"section__content\">Avant la normalisation claire par ISO\/IEC11801, les d\u00e9signations des types de blindage n&rsquo;\u00e9taient pas uniformes et cr\u00e9aient une certaine confusion sur le march\u00e9. Cette norme a introduit le sch\u00e9ma de d\u00e9signation suivant. <\/p><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"box\"><h3 class=\"section__heading\"><\/h3><div class=\"section__content\"><p class=\"section__content\"> <br\/>Par exemple : S\/UTP pour un c\u00e2ble r\u00e9seau avec tresse comme blindage total mais sans blindage individuel, ou SF\/FTP pour un c\u00e2ble r\u00e9seau avec tresse et feuillard comme blindage total et feuillard comme blindage sur chaque paire.<\/p><\/div><\/div><\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-key-info section section--key-info theme--dark section--animation-none\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"box\"><h3 class=\"section__heading\">Blindage<\/h3><div class=\"section__content\"><p class=\"section__content\">Une mise \u00e0 la terre qui entoure le noyau du c\u00e2ble (blindage global) o\u00f9 chaque paire de fils (blindage par paire) am\u00e9liore consid\u00e9rablement la qualit\u00e9 du signal en termes d&rsquo;immunit\u00e9 aux interf\u00e9rences, au rayonnement et aux interactions avec les autres lignes. Sur les connecteurs, ce blindage est ensuite reli\u00e9 au bo\u00eetier m\u00e9tallique du connecteur, qui \u00e9tablit la connexion \u00e0 la terre via la prise \u00e9lectrique de l&rsquo;appareil. Sans ce blindage, cette connexion n&rsquo;existe pas en raison de l&rsquo;isolation galvanique cr\u00e9\u00e9e par les transformateurs utilis\u00e9s. <\/p><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"box\"><h3 class=\"section__heading\"><\/h3><div class=\"section__content\"><p class=\"section__content\"><br\/>S&rsquo;applique g\u00e9n\u00e9ralement au blindage : plus c&rsquo;est dense, plus c&rsquo;est efficace. Le blindage individuel des paires a \u00e9galement des effets positifs clairs et mesurables. C&rsquo;est pourquoi certaines des cat\u00e9gories de c\u00e2bles les plus \u00e9lev\u00e9es (par ex. Cat.7) avec leurs d\u00e9bits de donn\u00e9es \u00e9lev\u00e9s utilisent deux blindages: individuel par paire et global. N\u00e9anmoins, dans les cat\u00e9gories inf\u00e9rieures, cat.5e et cat.6, on utilise traditionnellement des c\u00e2bles non blind\u00e9s. Les principaux types de blindage sont d\u00e9crits ci-dessous.<\/p><\/div><\/div><\/div><\/div><\/div><\/section>\n\n\n\n<section id=\"uutp\" class=\"wp-block-lindy-anchor-section section section--anchor\"><\/section>\n\n\n\n<section class=\"wp-block-lindy-contained-image section section--contained-image contained-image theme--light align--center font--size-medium\"><div class=\"contained\"><img decoding=\"async\" src=\"https:\/\/lindy.com\/fr\/wp-content\/uploads\/sites\/4\/2019\/10\/UUTP_FR.gif\"\/><a class=\"contained-image__replay\">Replay?<\/a><div class=\"contained-image__content\"><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-key-info section section--key-info theme--dark section--animation-none\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"box\"><h3 class=\"section__heading\">Unshielded Twisted Pair*<\/h3><div class=\"section__content\"><p class=\"section__content\">*Paires torsad\u00e9es non blind\u00e9es &#8211; un c\u00e2ble compl\u00e8tement non blind\u00e9 qui est encore souvent utilis\u00e9 dans le monde entier pour les cat\u00e9gories de c\u00e2bles inf\u00e9rieures: Cat.5 et Cat.6 (\u00e0 l&rsquo;exception de l&rsquo;Allemagne et de la Suisse). Cela signifie qu&rsquo;ils sont g\u00e9n\u00e9ralement suffisants pour les m\u00e9thodes de transmission des r\u00e9seaux jusqu&rsquo;au Gigabit Ethernet, m\u00eame s&rsquo;ils ne sont pas optimaux. Ceci dit, dans deux cas, il peut m\u00eame \u00eatre pr\u00e9f\u00e9rable d&rsquo;utiliser des c\u00e2bles non blind\u00e9s.<br\/><br\/>Tout d&rsquo;abord, s&rsquo;il y a de grandes diff\u00e9rences de potentiel (tension \u00e9lectrique) entre deux points et si les appareils r\u00e9seau utilis\u00e9s sont eux-m\u00eames connect\u00e9s \u00e0 la terre via leur c\u00e2ble d&rsquo;alimentation, une deuxi\u00e8me connexion de terre et donc une boucle de masse est cr\u00e9\u00e9e.<br\/><br\/><\/p><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"box\"><h3 class=\"section__heading\"><\/h3><div class=\"section__content\"><p class=\"section__content\">Cette boucle de masse g\u00e9n\u00e8re des courants de compensation basse fr\u00e9quence par l&rsquo;interm\u00e9diaire du blindage du c\u00e2ble, ce qui alt\u00e8re \u00e9norm\u00e9ment la qualit\u00e9 du signal. Deuxi\u00e8mement, certains syst\u00e8mes d&rsquo;extension AV ou USB qui utilisent des c\u00e2bles RJ45 sont plus d\u00e9pendants d&rsquo;une bonne diaphonie que d&rsquo;un bon blindage et fonctionnent donc mieux avec des c\u00e2bles non blind\u00e9s.<br\/><br\/>Comme ce type de c\u00e2ble n&rsquo;a pas de blindage et doit quand m\u00eame r\u00e9pondre aux exigences de sa cat\u00e9gorie, ses valeurs de diaphonie NeXT et FeXT (Near end crosstalk, Far end crosstalk : diaphonie locale et diaphonie distante) sont en g\u00e9n\u00e9ral meilleures. Pour ce faire, les paires torsad\u00e9es sont souvent s\u00e9par\u00e9es par des entretoises sp\u00e9ciales en plastique \u00e0 l&rsquo;int\u00e9rieur de la gaine du c\u00e2ble.<\/p><\/div><\/div><\/div><\/div><\/div><\/section>\n\n\n\n<section id=\"futp\" class=\"wp-block-lindy-anchor-section section section--anchor\"><\/section>\n\n\n\n<section class=\"wp-block-lindy-contained-image section section--contained-image contained-image theme--light align--center font--size-medium\"><div class=\"contained\"><img decoding=\"async\" src=\"https:\/\/lindy.com\/fr\/wp-content\/uploads\/sites\/4\/2019\/10\/FUTP_FR.gif\"\/><a class=\"contained-image__replay\">Replay?<\/a><div class=\"contained-image__content\"><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-key-info section section--key-info theme--dark section--animation-none\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"box\"><h3 class=\"section__heading\">Foiled Unshielded Twisted Pair*\n<\/h3><div class=\"section__content\"><p class=\"section__content\">*Paires torsad\u00e9es non blind\u00e9es avec feuillard global. Si vous pensez \u00e0 un c\u00e2ble U\/UTP envelopp\u00e9 dans un blindage en feuille d&rsquo;aluminium, le r\u00e9sultat est un c\u00e2ble F\/UTP. Pendant longtemps, ce type de blindage a \u00e9t\u00e9 le plus fr\u00e9quemment utilis\u00e9 et est plus que suffisant pour les cat\u00e9gories de c\u00e2bles Cat.5 et Cat.6 et le Gigabit Ethernet. Il optimise de mani\u00e8re significative la qualit\u00e9 du signal par rapport aux c\u00e2bles U\/UTP. <\/p><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"box\"><h3 class=\"section__heading\"><\/h3><div class=\"section__content\"><p class=\"section__content\"><\/p><\/div><\/div><\/div><\/div><\/div><\/section>\n\n\n\n<section id=\"sftp\" class=\"wp-block-lindy-anchor-section section section--anchor\"><\/section>\n\n\n\n<section class=\"wp-block-lindy-contained-image section section--contained-image contained-image theme--light align--center font--size-medium\"><div class=\"contained\"><img decoding=\"async\" src=\"https:\/\/lindy.com\/fr\/wp-content\/uploads\/sites\/4\/2019\/10\/SFTP_FR.gif\"\/><a class=\"contained-image__replay\">Replay?<\/a><div class=\"contained-image__content\"><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-key-info section section--key-info theme--light section--animation-none\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"box\"><h3 class=\"section__heading\">S\/FTP &#8211; Screened Foiled Twisted Pair*\n\n<\/h3><div class=\"section__content\"><p class=\"section__content\">*Paires torsad\u00e9es blind\u00e9es avec un feuillard, avec tresse globale. Ce type de blindage par tresse autour du c\u00e2ble et par feuillard autour des paires torsad\u00e9es est parfois appel\u00e9 c\u00e2ble PiMF (Pair in Metal Foil, paires dans un feuillard m\u00e9tal). Il repr\u00e9sente le blindage le plus \u00e9lev\u00e9 et doit donc \u00eatre utilis\u00e9 pour certaines cat\u00e9gories de c\u00e2bles (Cat.7, Cat.7A et Cat.8.2). <\/p><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"box\"><h3 class=\"section__heading\"><\/h3><div class=\"section__content\"><p class=\"section__content\"><br\/><br\/>La tresse m\u00e9tallique du blindage global doit avoir une couverture sup\u00e9rieure \u00e0 30 % afin d&rsquo;obtenir un blindage suffisant contre les interf\u00e9rences basses fr\u00e9quences (et donc ondes longues).<\/p><\/div><\/div><\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-related-links section image-columns-block theme--dark\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"grid\"><div class=\"col-7_xs-12\"><div class=\"section__content\"><h2 class=\"related-links__heading\">APER\u00c7U<\/h2><div class=\"related-links__content\">Retourner \u00e0 notre gamme de cordons et solutions r\u00e9seau<\/div><a href=\"https:\/\/lindy.com\/fr\/technologie\/cables-patch\/\" class=\"cta-link section__link\" target=\"_blank\" rel=\"noopener noreferrer\">D\u00e9couvrir<\/a><\/div><\/div><div class=\"col-5_xs-12\"><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"grid\"><div class=\"col-7_xs-12\"><div class=\"section__content\"><h2 class=\"related-links__heading\">GUIDE DE CAT\u00c9GORIE<\/h2><div class=\"related-links__content\">D\u00e9couvrez quelle cat\u00e9gorie de c\u00e2ble correspond \u00e0 vos besoins. <\/div><a href=\"https:\/\/lindy.com\/fr\/technologie\/categories-de-cable\/\" class=\"cta-link section__link\" target=\"_blank\" rel=\"noopener noreferrer\">D\u00e9couvrir<\/a><\/div><\/div><div class=\"col-5_xs-12\"><\/div><\/div><\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-related-links section image-columns-block theme--dark\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"grid\"><div class=\"col-7_xs-12\"><div class=\"section__content\"><h2 class=\"related-links__heading\">COMPARER <\/h2><div class=\"related-links__content\">Comparez les caract\u00e9ristiques de performance des cordons patch Lindy et trouvez le cordon adapt\u00e9 \u00e0 votre application. <\/div><a href=\"https:\/\/lindy.com\/fr\/technologie\/performance-des-cables-patch-reseau\/\" class=\"cta-link section__link\" target=\"_blank\" rel=\"noopener noreferrer\">D\u00e9couvrir<\/a><\/div><\/div><div class=\"col-5_xs-12\"><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"grid\"><div class=\"col-7_xs-12\"><div class=\"section__content\"><h2 class=\"related-links__heading\">CERTIFICATS  <\/h2><div class=\"related-links__content\">D\u00e9couvrez comment Lindy r\u00e9pond aux standards du march\u00e9 dans la connectivit\u00e9 des r\u00e9seaux. <\/div><a href=\"https:\/\/lindy.com\/fr\/technologie\/cables-reseau-patch-certificats\/\" class=\"cta-link section__link\" target=\"_blank\" rel=\"noopener noreferrer\">D\u00e9couvrir<\/a><\/div><\/div><div class=\"col-5_xs-12\"><\/div><\/div><\/div><\/div><\/div><\/section>\n","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":0,"template":"","class_list":["post-786","lin-technology","type-lin-technology","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Patch Cable Shielding - Lindy - French<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Patch Cable Shielding - Lindy - French\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/\" \/>\n<meta property=\"og:site_name\" content=\"Lindy - French\" \/>\n<meta property=\"article:modified_time\" content=\"2019-11-11T15:33:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/\",\"url\":\"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/\",\"name\":\"Patch Cable Shielding - Lindy - French\",\"isPartOf\":{\"@id\":\"https:\/\/lindy.com\/fr\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg\",\"datePublished\":\"2019-10-10T08:55:02+00:00\",\"dateModified\":\"2019-11-11T15:33:09+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/#primaryimage\",\"url\":\"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg\",\"contentUrl\":\"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/lindy.com\/fr\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Patch Cable Shielding\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/lindy.com\/fr\/#website\",\"url\":\"https:\/\/lindy.com\/fr\/\",\"name\":\"Lindy - French\",\"description\":\"Connection Perfection\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/lindy.com\/fr\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Patch Cable Shielding - Lindy - French","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/","og_locale":"fr_FR","og_type":"article","og_title":"Patch Cable Shielding - Lindy - French","og_url":"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/","og_site_name":"Lindy - French","article_modified_time":"2019-11-11T15:33:09+00:00","og_image":[{"url":"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/","url":"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/","name":"Patch Cable Shielding - Lindy - French","isPartOf":{"@id":"https:\/\/lindy.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/#primaryimage"},"image":{"@id":"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/#primaryimage"},"thumbnailUrl":"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg","datePublished":"2019-10-10T08:55:02+00:00","dateModified":"2019-11-11T15:33:09+00:00","breadcrumb":{"@id":"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/#primaryimage","url":"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg","contentUrl":"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/lindy.com\/fr\/technologie\/construction-du-cable\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/lindy.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Patch Cable Shielding"}]},{"@type":"WebSite","@id":"https:\/\/lindy.com\/fr\/#website","url":"https:\/\/lindy.com\/fr\/","name":"Lindy - French","description":"Connection Perfection","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lindy.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/lindy.com\/fr\/wp-json\/wp\/v2\/lin-technology\/786","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lindy.com\/fr\/wp-json\/wp\/v2\/lin-technology"}],"about":[{"href":"https:\/\/lindy.com\/fr\/wp-json\/wp\/v2\/types\/lin-technology"}],"version-history":[{"count":0,"href":"https:\/\/lindy.com\/fr\/wp-json\/wp\/v2\/lin-technology\/786\/revisions"}],"wp:attachment":[{"href":"https:\/\/lindy.com\/fr\/wp-json\/wp\/v2\/media?parent=786"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}