{"id":726,"date":"2019-10-10T15:25:55","date_gmt":"2019-10-10T15:25:55","guid":{"rendered":"https:\/\/lindy.com\/it\/?post_type=lin-technology&#038;p=726"},"modified":"2019-11-11T15:34:14","modified_gmt":"2019-11-11T15:34:14","slug":"cavo-patch-tipi-di-schermatura","status":"publish","type":"lin-technology","link":"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/","title":{"rendered":"Patch Cable Shielding"},"content":{"rendered":"\n<section class=\"wp-block-lindy-image-text-module section section--full-width-image full-width-image--with-text theme--light section--animation-none align--center  font--size-medium\" style=\"background-image:url(https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg)\"><img decoding=\"async\" class=\"full-width-image__image\" src=\"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg\"\/><div class=\"contained\"><div class=\"full-width-image__content\"><h2 class=\"section__heading\"><span>STRUTTURA DEI CAVI<\/span><\/h2><h2 class=\"section__subheading section__subheading__title\">CAVI DI RETE E RELATIVI TIPI DI SCHERMATURA<\/h2><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-paragraph-one-col section section--horizontal-content section--horizontal-content--one-column font--size-small theme--dark align--center  section--animation-up\"><div class=\"contained\"><p class=\"section__paragraph\">I cavi con doppini ritorti sono generalmente costituiti da quattro coppie di fili (quattro doppini) ritorti. La torsione serve a ridurre al minimo la capacit\u00e0 parassita, che altrimenti pregiudicherebbe fortemente la qualit\u00e0 di trasmissione del cavo, specialmente nelle bande ad alta frequenza con elevati valori di attenuazione del segnale, che tende a verificarsi quando le coppie di fili sono disposte in parallelo. <br\/><br\/>Le quattro coppie di fili sono anch&#8217;esse intrecciate tra di loro nel cavo per ridurre al minimo la diafonia vicina e lontana tra le coppie (NeXT e FeXT). Questo fascio di cavi \u00e8 chiamato anima ed \u00e8 ricoperto da una guaina. A seconda del tipo di schermatura, le singole coppie di fili, o anima del cavo (o entrambi o nessuno di essi), sono avvolti da una lamina metallica o protetti da una schermatura intrecciata.<\/p><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-image-text-module section section--full-width-image full-width-image--with-text theme--light section--animation-none align--left  font--size-medium\" style=\"background-image:url(https:\/\/lindy.com\/it\/wp-content\/uploads\/sites\/5\/2019\/10\/Animation-Nomenklatur_IT-2.gif)\"><img decoding=\"async\" class=\"full-width-image__image\" src=\"https:\/\/lindy.com\/it\/wp-content\/uploads\/sites\/5\/2019\/10\/Animation-Nomenklatur_IT-2.gif\"\/><div class=\"contained\"><div class=\"full-width-image__content\"><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-key-info section section--key-info theme--light section--animation-none\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"box\"><h3 class=\"section__heading\">\nNomenclatura della schermatura<\/h3><div class=\"section__content\"><p class=\"section__content\">Prima della standardizzazione univoca con la norma ISO\/IEC11801, le denominazioni dei tipi di schermatura non erano unitarie e causavano spesso confusione sul mercato. Questa norma ha introdotto uno schema di designazione. <\/p><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"box\"><h3 class=\"section__heading\"><\/h3><div class=\"section__content\"><p class=\"section__content\"> <br\/>Eccone un esempio: S\/FTP per cavi TP con intreccio come schermatura totale e con schermatura sulle singole coppie, o SF\/FTP per cavi TP con intreccio e lamina come schermatura totale e lamina come schermatura singola.<\/p><\/div><\/div><\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-key-info section section--key-info theme--dark section--animation-none\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"box\"><h3 class=\"section__heading\">Schermatura<\/h3><div class=\"section__content\"><p class=\"section__content\">Normalmente un collegamento a terra che avvolge l&#8217;anima del cavo (schermatura totale) o singole coppie di fili (schermatura singola) migliora in modo significativo la qualit\u00e0 del segnale in termini di immunit\u00e0 alle interferenze e alle radiazioni, interazione con altre linee e sicurezza di intercettazione di un collegamento di trasmissione. Questo schermo viene poi collegato ai connettori tramite l&#8217;alloggiamento metallico del connettore, che stabilisce il collegamento a terra attraverso la presa dell&#8217;apparecchio. <\/p><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"box\"><h3 class=\"section__heading\"><\/h3><div class=\"section__content\"><p class=\"section__content\"><br\/>Senza schermatura, questo collegamento non potrebbe sussistere per via dell&#8217;isolamento galvanico causato dai trasformatori di isolamento utilizzati nelle tecnologie di rete. In genere, per quanto riguarda la schermatura vale la seguente regola: pi\u00f9 un cavo \u00e8 schermato, pi\u00f9 \u00e8 denso e di conseguenza pi\u00f9 efficace. Anche la schermatura di singole coppie di fili in questo senso ha effetti positivi evidenti e misurabili. Per questo motivo alcune categorie di cavi pi\u00f9 elevate (ad es. Cat.7) con la loro spiccata velocit\u00e0 di trasmissione dei dati richiedono cavi con schermatura singola e totale. Tuttavia, nelle categorie inferiori Cat.5e e Cat.6 solitamente vengono utilizzati anche cavi completamente non schermati. Qui di seguito vengono descritti i tipi di schermatura pi\u00f9 importanti.  <\/p><\/div><\/div><\/div><\/div><\/div><\/section>\n\n\n\n<section id=\"uutp\" class=\"wp-block-lindy-anchor-section section section--anchor\"><\/section>\n\n\n\n<section class=\"wp-block-lindy-contained-image section section--contained-image contained-image theme--light align--center font--size-medium\"><div class=\"contained\"><img decoding=\"async\" src=\"https:\/\/lindy.com\/it\/wp-content\/uploads\/sites\/5\/2019\/10\/UUTP_IT.gif\"\/><a class=\"contained-image__replay\">Replay?<\/a><div class=\"contained-image__content\"><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-key-info section section--key-info theme--dark section--animation-none\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"box\"><h3 class=\"section__heading\">Unshielded Twisted Pair\n<\/h3><div class=\"section__content\"><p class=\"section__content\">Unshielded\/Unshielded Twisted Pair: si tratta di un cavo completamente non schermato, che viene ancora spesso utilizzato per le categorie di cavi inferiori Cat.5 e Cat.6 (curiosamente fatta eccezione per Germania e Svizzera). Ci\u00f2 significa che in genere il loro utilizzo \u00e8 soddisfacente per le operazioni di trasmissione delle reti fino a Gigabit Ethernet, anche se non ottimale. Tuttavia, si contano due casi in cui l\u2019utilizzo di cavi non schermati \u00e8 la scelta ideale.<br\/><br\/>Il primo caso si verifica quando vi sono grandi differenze di tensione del potenziale di riferimento tra i punti terminali e gli apparecchi di rete utilizzati sono essi stessi collegati a terra o al potenziale di terra attraverso il contatto PE del cavo di alimentazione; in questo modo si crea un secondo collegamento a terra e quindi un cosiddetto \u201ccircuito di messa a terra\u201d. <br\/><br\/><\/p><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"box\"><h3 class=\"section__heading\"><\/h3><div class=\"section__content\"><p class=\"section__content\"><br\/>Ci\u00f2 genera correnti di compensazione a bassa frequenza attraverso lo schermo del cavo, che compromettono notevolmente la qualit\u00e0 del segnale. Il secondo caso si verifica perch\u00e9 alcuni sistemi Extender AV o USB che utilizzano cavi Cat.X dipendono pi\u00f9 da una buona diafonia che da una buona schermatura e pertanto funzionano meglio con cavi non schermati. <br\/><br\/>Poich\u00e9 questo tipo di cavo non necessita di schermatura, ma deve comunque soddisfare i requisiti della sua categoria, presenta solitamente valori NeXT e FeXT molto migliori. Per raggiungere queste prestazioni, le sue coppie di fili sono spesso separate da speciali distanziatori in plastica posti all&#8217;interno della guaina del cavo.<\/p><\/div><\/div><\/div><\/div><\/div><\/section>\n\n\n\n<section id=\"futp\" class=\"wp-block-lindy-anchor-section section section--anchor\"><\/section>\n\n\n\n<section class=\"wp-block-lindy-contained-image section section--contained-image contained-image theme--light align--center font--size-medium\"><div class=\"contained\"><img decoding=\"async\" src=\"https:\/\/lindy.com\/it\/wp-content\/uploads\/sites\/5\/2019\/10\/FUTP_IT.gif\"\/><a class=\"contained-image__replay\">Replay?<\/a><div class=\"contained-image__content\"><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-key-info section section--key-info theme--dark section--animation-none\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"box\"><h3 class=\"section__heading\">Foiled Unshielded Twisted Pair\n<\/h3><div class=\"section__content\"><p class=\"section__content\">Se si pensa all&#8217;anima di un cavo U\/UTP avvolta in una pellicola in plastica rivestita di alluminio, ci\u00f2 che ne risulta \u00e8 un cavo F\/UTP. Per molto tempo questo tipo di schermatura \u00e8 stato il pi\u00f9 utilizzato e risulta infatti pi\u00f9 che sufficiente per le categorie di cavi Cat.5 e Cat.6 e per gli standard di trasmissione fino a Gigabit Ethernet. Di solito ottimizza significativamente la qualit\u00e0 del segnale rispetto ai cavi U\/UTP. <\/p><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"box\"><h3 class=\"section__heading\"><\/h3><div class=\"section__content\"><p class=\"section__content\"><\/p><\/div><\/div><\/div><\/div><\/div><\/section>\n\n\n\n<section id=\"sftp\" class=\"wp-block-lindy-anchor-section section section--anchor\"><\/section>\n\n\n\n<section class=\"wp-block-lindy-contained-image section section--contained-image contained-image theme--light align--center font--size-medium\"><div class=\"contained\"><img decoding=\"async\" src=\"https:\/\/lindy.com\/it\/wp-content\/uploads\/sites\/5\/2019\/10\/SFTP_IT.gif\"\/><a class=\"contained-image__replay\">Replay?<\/a><div class=\"contained-image__content\"><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-key-info section section--key-info theme--light section--animation-none\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"box\"><h3 class=\"section__heading\">Screened Foiled Twisted Pair\n<\/h3><div class=\"section__content\"><p class=\"section__content\">Questa variante con schermatura intrecciata all&#8217;anima del cavo e rivestimento in lamina sulle singole coppie di fili \u00e8 talvolta definita cavo PiMF (Pair in Metal Foil). Questo tipo di schermatura \u00e8 il pi\u00f9 robusto e deve pertanto essere necessariamente impiegato per alcune categorie di cavi (Cat.7, Cat.7A e Cat.8.2).<\/p><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"box\"><h3 class=\"section__heading\"><\/h3><div class=\"section__content\"><p class=\"section__content\"><br\/><br\/>La protezione metallica della schermatura totale dovrebbe presentare un grado di copertura superiore al 30% per garantire una protezione sufficiente contro le interferenze tipiche delle basse frequenze (e quindi di lunghezza d\u2019onda lunga).<\/p><\/div><\/div><\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-related-links section image-columns-block theme--dark\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"grid\"><div class=\"col-7_xs-12\"><div class=\"section__content\"><h2 class=\"related-links__heading\">PANORAMICA<\/h2><div class=\"related-links__content\">Ritorna alla nostra vasta gamma di cavi di rete e di soluzioni patch<\/div><a href=\"https:\/\/lindy.com\/it\/technology\/cavi-patch\/\" class=\"cta-link section__link\" target=\"_blank\" rel=\"noopener noreferrer\">Scopri di piu&#8217;<\/a><\/div><\/div><div class=\"col-5_xs-12\"><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"grid\"><div class=\"col-7_xs-12\"><div class=\"section__content\"><h2 class=\"related-links__heading\">GUIDA ALLA CATEGORIA<\/h2><div class=\"related-links__content\">Scopri di pi\u00f9 su quale categoria di cavi si adatta meglio alle tue esigenze di mercato<\/div><a href=\"https:\/\/lindy.com\/it\/technology\/cavo-patch-categorie\/\" class=\"cta-link section__link\" target=\"_blank\" rel=\"noopener noreferrer\">Scopri di piu&#8217;<\/a><\/div><\/div><div class=\"col-5_xs-12\"><\/div><\/div><\/div><\/div><\/div><\/section>\n\n\n\n<section class=\"wp-block-lindy-related-links section image-columns-block theme--dark\"><div class=\"contained\"><div class=\"grid-2_sm-1-center\"><div class=\"col left_item\"><div class=\"grid\"><div class=\"col-7_xs-12\"><div class=\"section__content\"><h2 class=\"related-links__heading\">CONFRONTA<\/h2><div class=\"related-links__content\">Confronta le caratteristiche prestazionali dei cavi patch Lindy e trova l&#8217;abbinamento perfetto per la tua applicazione<\/div><a href=\"https:\/\/lindy.com\/it\/technology\/cavo-patch-funzionalita\/\" class=\"cta-link section__link\" target=\"_blank\" rel=\"noopener noreferrer\">Scopri di piu&#8217;<\/a><\/div><\/div><div class=\"col-5_xs-12\"><\/div><\/div><\/div><div class=\"col right_item\"><div class=\"grid\"><div class=\"col-7_xs-12\"><div class=\"section__content\"><h2 class=\"related-links__heading\">CERTIFICATI<\/h2><div class=\"related-links__content\">Per saperne di pi\u00f9 su come Lindy soddisfa gli standard di mercato nella connettivit\u00e0 di rete<\/div><a href=\"https:\/\/lindy.com\/it\/technology\/cavo-patch-certificati\/\" class=\"cta-link section__link\" target=\"_blank\" rel=\"noopener noreferrer\">Scopri di piu&#8217;<\/a><\/div><\/div><div class=\"col-5_xs-12\"><\/div><\/div><\/div><\/div><\/div><\/section>\n","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":0,"template":"","class_list":["post-726","lin-technology","type-lin-technology","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Patch Cable Shielding - Lindy - Italian<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Patch Cable Shielding - Lindy - Italian\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/\" \/>\n<meta property=\"og:site_name\" content=\"Lindy - Italian\" \/>\n<meta property=\"article:modified_time\" content=\"2019-11-11T15:34:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/\",\"url\":\"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/\",\"name\":\"Patch Cable Shielding - Lindy - Italian\",\"isPartOf\":{\"@id\":\"https:\/\/lindy.com\/it\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg\",\"datePublished\":\"2019-10-10T15:25:55+00:00\",\"dateModified\":\"2019-11-11T15:34:14+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/#primaryimage\",\"url\":\"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg\",\"contentUrl\":\"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/lindy.com\/it\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Patch Cable Shielding\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/lindy.com\/it\/#website\",\"url\":\"https:\/\/lindy.com\/it\/\",\"name\":\"Lindy - Italian\",\"description\":\"Connection Perfection\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/lindy.com\/it\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Patch Cable Shielding - Lindy - Italian","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/","og_locale":"it_IT","og_type":"article","og_title":"Patch Cable Shielding - Lindy - Italian","og_url":"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/","og_site_name":"Lindy - Italian","article_modified_time":"2019-11-11T15:34:14+00:00","og_image":[{"url":"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Tempo di lettura stimato":"4 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/","url":"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/","name":"Patch Cable Shielding - Lindy - Italian","isPartOf":{"@id":"https:\/\/lindy.com\/it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/#primaryimage"},"image":{"@id":"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/#primaryimage"},"thumbnailUrl":"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg","datePublished":"2019-10-10T15:25:55+00:00","dateModified":"2019-11-11T15:34:14+00:00","breadcrumb":{"@id":"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/#primaryimage","url":"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg","contentUrl":"https:\/\/lindy.com\/en\/wp-content\/uploads\/sites\/2\/2019\/09\/Shielding-4.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/lindy.com\/it\/technology\/cavo-patch-tipi-di-schermatura\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/lindy.com\/it\/"},{"@type":"ListItem","position":2,"name":"Patch Cable Shielding"}]},{"@type":"WebSite","@id":"https:\/\/lindy.com\/it\/#website","url":"https:\/\/lindy.com\/it\/","name":"Lindy - Italian","description":"Connection Perfection","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lindy.com\/it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"}]}},"_links":{"self":[{"href":"https:\/\/lindy.com\/it\/wp-json\/wp\/v2\/lin-technology\/726","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lindy.com\/it\/wp-json\/wp\/v2\/lin-technology"}],"about":[{"href":"https:\/\/lindy.com\/it\/wp-json\/wp\/v2\/types\/lin-technology"}],"version-history":[{"count":0,"href":"https:\/\/lindy.com\/it\/wp-json\/wp\/v2\/lin-technology\/726\/revisions"}],"wp:attachment":[{"href":"https:\/\/lindy.com\/it\/wp-json\/wp\/v2\/media?parent=726"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}